- Server
- System Design Guideline
- Published:2014-08-28
Rigid System Design Guideline
High Performance/ Fanless/Low Noise
The challenge is to transfer effectively the heating power from the controller and chipset to the outside of the system only by raised radiating fin, which needs careful calculation to the whole heat exchange mode system. All Rigid series products will need to test the reliability and stability of fanless working status under -40~70°C.
Starting Memory Support
* @ 70°C, system on & off 1000 times
* @-40°C, system on & off 1000 times
* @70°C, system burning
testing
* @-40°C, system
burning testing
* @70°C, dram
testing
* @Vibration Testing: 3 Grms/5~500Hz/Free Operation
* Shock Testing
- Working Status
- Working Status 20G (11ms), No-working status 40G HDD
- Destroy
Multiple Display Port
Mechanical Design
Take heat distribution, system layout, surface heat transfer and hot spot into consideration in the mechanical design to achieve the best heat radiating results.
Expand widely